ASTM G120-2001 索格利特萃取法测定可溶性残余杂质的标准试验方法
作者:标准资料网
时间:2024-05-03 13:45:42
浏览:8522
来源:标准资料网
下载地址: 点击此处下载
【英文标准名称】:StandardPracticeforDeterminationofSolubleResidualContaminationinbySoxhletExtraction
【原文标准名称】:索格利特萃取法测定可溶性残余杂质的标准试验方法
【标准号】:ASTMG120-2001
【标准状态】:现行
【国别】:
【发布日期】:2001
【实施或试行日期】:
【发布单位】:美国材料与试验协会(US-ASTM)
【起草单位】:G04.02
【标准类型】:(Practice)
【标准水平】:()
【中文主题词】:
【英文主题词】:contaminant;contamination;extraction;nonvolatileresidue;oxygensystems;Soxhletextraction
【摘要】:Itisexpectedthatthistestmethodwillbesuitabletoidentifyandquantifycontaminantsfoundinsystems,systemmaterials,andcomponentsusedinsystemsrequiringahighlevelofcleanliness,suchasoxygen.Softgoodssuchassealsandvalveseatscanbetestedasreceived.Glovesandwipes,orsamplesthereof,tobeusedinthecleaningoperationcanbeevaluatedpriortousetoensurethattheproposedcleaningsolventdoesnotextractcontaminantsandresiduesonthesurfacetobecleaned.Wipesorothercleaningequipmentcanbetestedafterusetodeterminetheamountofcontaminantremovedfromasurface.ThisprocedurecanbeusedtoobtainsamplesforNVRanalysisusingcontaminatedcontrolcouponsthatweresubjectedtothecleaningprocessascontrolstovalidatecleaningoperations.Theselectionofthesolventrequiressomeknowledgeofthecontaminant(seePracticeG93forrecommendations).Ifanonvolatileresidue(NVR)analysisistobeperformedonthemolecularcontaminant,theboilingpointofthesolventshallbesignificantlylowerthanthatofthecontaminant.Forotheranalyticalmethods,thetestermustknowtheaccuracyoftheanalyticalmethods,andthesolventshallbechosensoasnottointerferewiththeselectedanalyticalmethod.ToidentifythecompositionoftheNVR,analyticalmethodssuchasinfraredspectroscopyorgaschromatography/massspectroscopyhavebeenusedsatisfactorily.1.1Thispracticedescribesaprocedureforthedeterminationofresidualcontaminationinsystemsandcomponentsrequiringahighlevelofcleanliness,suchasoxygen,bySoxhletextraction.1.2Thispracticemaybeusedforextractingnonvolatileandsemivolatileresiduesfromsolidssuchasnewandusedgloves,newandusedwipes,contaminatedtestspecimensorcontrolcoupons,smallpiecesofhardware,componentsoftgoods,etc.Whenusedwithproposedcleaningmaterials(wipes,gloves,etc.),thispracticemaybeusedtodeterminethepotentialoftheproposedsolventtoextractcontaminants(plasticizers,residualdetergents,brighteners,etc.)anddepositthemonthesurfacebeingcleaned.1.3Thispracticeisnotsuitablefortheevaluationofparticulatecontamination.1.4ThevaluesstatedinSIunitsarestandard.Valuesinparenthesesareforinformationonly.1.5Thisstandarddoesnotpurporttoaddressallofthesafetyconcerns,ifany,associatedwithitsuse.Itistheresponsibilityoftheuserofthisstandardtoestablishappropriatesafetyandhealthpracticesanddeterminetheapplicabilityofregulatorylimitationspriortouse.
【中国标准分类号】:Z13
【国际标准分类号】:71_040_40
【页数】:4P.;A4
【正文语种】:
【原文标准名称】:索格利特萃取法测定可溶性残余杂质的标准试验方法
【标准号】:ASTMG120-2001
【标准状态】:现行
【国别】:
【发布日期】:2001
【实施或试行日期】:
【发布单位】:美国材料与试验协会(US-ASTM)
【起草单位】:G04.02
【标准类型】:(Practice)
【标准水平】:()
【中文主题词】:
【英文主题词】:contaminant;contamination;extraction;nonvolatileresidue;oxygensystems;Soxhletextraction
【摘要】:Itisexpectedthatthistestmethodwillbesuitabletoidentifyandquantifycontaminantsfoundinsystems,systemmaterials,andcomponentsusedinsystemsrequiringahighlevelofcleanliness,suchasoxygen.Softgoodssuchassealsandvalveseatscanbetestedasreceived.Glovesandwipes,orsamplesthereof,tobeusedinthecleaningoperationcanbeevaluatedpriortousetoensurethattheproposedcleaningsolventdoesnotextractcontaminantsandresiduesonthesurfacetobecleaned.Wipesorothercleaningequipmentcanbetestedafterusetodeterminetheamountofcontaminantremovedfromasurface.ThisprocedurecanbeusedtoobtainsamplesforNVRanalysisusingcontaminatedcontrolcouponsthatweresubjectedtothecleaningprocessascontrolstovalidatecleaningoperations.Theselectionofthesolventrequiressomeknowledgeofthecontaminant(seePracticeG93forrecommendations).Ifanonvolatileresidue(NVR)analysisistobeperformedonthemolecularcontaminant,theboilingpointofthesolventshallbesignificantlylowerthanthatofthecontaminant.Forotheranalyticalmethods,thetestermustknowtheaccuracyoftheanalyticalmethods,andthesolventshallbechosensoasnottointerferewiththeselectedanalyticalmethod.ToidentifythecompositionoftheNVR,analyticalmethodssuchasinfraredspectroscopyorgaschromatography/massspectroscopyhavebeenusedsatisfactorily.1.1Thispracticedescribesaprocedureforthedeterminationofresidualcontaminationinsystemsandcomponentsrequiringahighlevelofcleanliness,suchasoxygen,bySoxhletextraction.1.2Thispracticemaybeusedforextractingnonvolatileandsemivolatileresiduesfromsolidssuchasnewandusedgloves,newandusedwipes,contaminatedtestspecimensorcontrolcoupons,smallpiecesofhardware,componentsoftgoods,etc.Whenusedwithproposedcleaningmaterials(wipes,gloves,etc.),thispracticemaybeusedtodeterminethepotentialoftheproposedsolventtoextractcontaminants(plasticizers,residualdetergents,brighteners,etc.)anddepositthemonthesurfacebeingcleaned.1.3Thispracticeisnotsuitablefortheevaluationofparticulatecontamination.1.4ThevaluesstatedinSIunitsarestandard.Valuesinparenthesesareforinformationonly.1.5Thisstandarddoesnotpurporttoaddressallofthesafetyconcerns,ifany,associatedwithitsuse.Itistheresponsibilityoftheuserofthisstandardtoestablishappropriatesafetyandhealthpracticesanddeterminetheapplicabilityofregulatorylimitationspriortouse.
【中国标准分类号】:Z13
【国际标准分类号】:71_040_40
【页数】:4P.;A4
【正文语种】:
下载地址:
点击此处下载